Inerter Duty Motors are designed for optimized
performance to run with variable frequency drive. The
Inverter Duty Motors have independent cooling fan to cool
down motor. It can operate for wide speed range without any
heating problem.
|
A standard motor driven by the inverter generates slightly less
power than it does. When it is driven with commercial power
supply, also, the cooling effect deteriorates in low speed range,
then the motor temperature rising increases.
Reduce load torque in the low speed range. Allowable load
characteristics of the standard motors are shown in the figure. If
100% continuous torque is required in the low speed range, use an
inverter duty motor is reliable. |
 |
|
|
|
|
|
[ Specification ] |
|
|
AVB
/ AVV 10HZ-160HZ |
|
|
|
MODEL |
AVB or AVV |
|
Frame No. |
80 |
90L |
100L |
112M |
132S |
132M |
160M |
160L |
|
Output (KW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11.0 |
15.0 |
|
Torque (Kg-M) |
0.43 |
0.85 |
1.27 |
2.11 |
3.17 |
4.22 |
6.33 |
8.44 |
|
RPM |
1725RPM at 60HZ |
|
Construction |
Total enclosed external cooling fan |
|
Pole |
4 |
|
Source |
3ψ220
or 380 or 440V |
|
V/F |
100﹪
Output/50-160HZ |
|
Torque Character |
Constant torque range |
10HZ- 60HZ |
|
Constant output range |
60HZ- 160HZ |
|
Starting Torque |
125﹪ |
|
Insulation |
F |
|
Duty |
Continue |
|
Environmental Condition |
-20 to 40 degree;humidity
100﹪;inside
of house;
without burst proof;not
more than 1000M |
|
Max. Speed |
4800RPM |
|
Base speed |
60HZ |
|
AVB: Base mount AVV: Flange mount |
|
|
|
AEEFV / AEVFV 10HZ-110HZ |
|
|
|
MODEL |
AEEFV or AEVFV |
|
Frame No. |
80 |
90L |
100L |
112M |
132S |
132M |
160M |
160L |
|
Output (KW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11.0 |
15.0 |
|
Torque (Kg-M) |
0.51 |
1.02 |
1.53 |
2.55 |
3.825 |
5.10 |
7.65 |
10.20 |
|
RPM |
1425RPM at 50HZ |
|
Construction |
Total enclosed external cooling fan |
|
Pole |
4 |
|
Source |
3ψ220
or 380 or 440V |
|
V/F |
100﹪
Output/50-110HZ |
|
Torque Character |
Constant torque range |
10HZ- 50HZ |
|
Constant output range |
50HZ- 110HZ |
|
Starting Torque |
125﹪ |
|
Insulation |
F |
|
Duty |
Continue |
|
Environmental Condition |
-20 to 40 degree;humidity
100﹪;inside
of house;
without burst proof;not
more than 1000M |
|
Max. Speed |
3300RPM |
|
Base speed |
50HZ |
|
AEEFV: Base mount AEVFV: Flange mount |
|
|
|
|
|
|
[ Motor Dimension ] |
|
|

Output
(kw) |
Frame
No. |
Pole |
H |
AD |
E |
F |
Z |
C |
P |
HD |
AC |
L |
M |
N |
Shaft |
Bearing |
|
ED |
D |
GD |
G |
W |
|
0.75 |
80 |
4 |
80 |
140 |
125 |
100 |
10 |
50 |
40 |
- |
177 |
328 |
155 |
130 |
35 |
19 |
6 |
15.5 |
6 |
6204ZZ |
6203 |
|
1.5 |
90L |
4 |
90 |
150 |
140 |
125 |
10 |
56 |
50 |
- |
200 |
341 |
170 |
150 |
45 |
24 |
7 |
20 |
8 |
6205ZZ |
6204 |
|
2.2 |
100L |
4 |
100 |
162 |
160 |
140 |
12 |
63 |
60 |
243 |
219 |
401 |
195 |
175 |
55 |
28 |
7 |
24 |
8 |
6206ZZ |
6205 |
|
3.7 |
112M |
4 |
112 |
169 |
190 |
140 |
12 |
70 |
60 |
265 |
238 |
420 |
224 |
175 |
55 |
28 |
7 |
24 |
8 |
6306ZZ |
6305 |
|
5.5 |
132S |
4 |
132 |
184 |
216 |
140 |
12 |
89 |
80 |
310 |
279 |
497 |
250 |
185 |
76 |
38 |
8 |
33 |
10 |
6308ZZ |
6306 |
|
7.5 |
132M |
4 |
132 |
184 |
216 |
178 |
12 |
89 |
80 |
310 |
279 |
533 |
250 |
212 |
76 |
38 |
8 |
33 |
10 |
6308ZZ |
6306 |
|
11.0 |
160M |
4 |
160 |
250 |
254 |
210 |
14.5 |
108 |
110 |
377 |
334 |
670 |
300 |
250 |
105 |
42 |
8 |
37 |
12 |
6309ZZ |
6307 |
|
15.0 |
160L |
4 |
160 |
250 |
254 |
254 |
14.5 |
108 |
110 |
377 |
334 |
722 |
300 |
300 |
105 |
42 |
8 |
37 |
12 |
6309ZZ |
6307 |
|
|
|
|
|
|
|
|
|
 |
|
|
Output
(kw) |
Frame
No. |
Pole |
ØP |
ØN |
AD |
ØM |
ØS |
AC |
L |
LB |
E |
LA |
T |
Shaft |
Bearing |
|
ED |
D |
GD |
G |
W |
|
0.75 |
80 |
4 |
200 |
130 |
140 |
165 |
12 |
177 |
338 |
286 |
40 |
12 |
3.5 |
35 |
19 |
6 |
15.5 |
6 |
6204 |
6203 |
|
1.5 |
90L |
4 |
200 |
130 |
149 |
165 |
12 |
200 |
390 |
328 |
50 |
12 |
3.5 |
45 |
24 |
7 |
20 |
8 |
6205 |
6204 |
|
2.2 |
100L |
4 |
250 |
180 |
162 |
215 |
15 |
220 |
403 |
| |