Vector
Inverters
High Performance and Powerful
|
|
|
|
|
|
|
|
Vector Inverters is a space vector PWM
control inverter with internal braking unit and DC braking
resistor. The Vector Inverters have higher torque, quiet, full of
functions to suit for all kinds of machines and can help you gain
multi-effect in work & make product become the most excellent.
|
|
|
|
|
|
[ Characteristic
]
Use DSP CPU space vector PWM control. |
RS485 Communication. |
Internal braking
unit and DC braking. |
Analog input signal:
0-10VDC, 4-20mA. |
Selection of free
running stop or dynamic braking stop. |
V/F curve
adjustable. |
Torque boost and
slip compensate automatically. |
4 internal ramps
(Linear / S-shaped). |
Speed pulse
generation output. |
Max. Torque current
limits. |
Internal PID
controller and timer. |
Restart search
frequency (Close loop). |
Master / slave
driver system. |
Phase to earth and
phase to phase short circuit protection. |
Use high efficiency
power module. |
8 internal speed
reference values and Jog operation. |
PG close loop control. |
|
|
|
|
|
|
[ Specification ]
| Model |
AP2G5 |
AP4G5 |
| Input
Voltage |
3Ø 220VAC ±10% |
3Ø 380/440VAC ±10% |
|
Model No |
37 |
55 |
75 |
110 |
150 |
185 |
220 |
37 |
55 |
75 |
110 |
150 |
185 |
220 |
| Input
Frequency |
50HZ / 60HZ ±5% |
|
Output Voltage |
3Ø
220VAC |
3Ø 380/440VAC |
| Output
Frequency |
0.1HZ ~ 400HZ |
|
Rated Current
(A) |
17 |
24 |
33 |
46 |
62 |
76 |
90 |
8.5 |
12 |
16.5 |
23 |
31 |
38 |
45 |
| Capacity
(KVA) |
6.5 |
9.2 |
12.6 |
17.6 |
23.6 |
29 |
34 |
6.5 |
9.2 |
12.6 |
17.6 |
23.6 |
29 |
34 |
|
Largest Motor
(4poles) (KW) |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
| Control
Method |
SV PWM |
|
Cooling Method |
Air-Cooled |
|
Approval |
None |
CSAcus |
None |
CSAcus |
| Weight
(KG) |
5.6 |
5.8 |
6.2 |
14.5 |
14.5 |
16 |
16 |
5.6 |
5.8 |
6.2 |
14.5 |
14.5 |
16 |
16 |
|
(mm) |
Fig1 |
Fig2 |
Fig1 |
Fig2 |
|
|
|
|
|
|
[ Feature ]
|
|
|
|
CONTROL FEATURE |
| Control Method |
Space Vector PWM (SV
PWM) |
|
Output Frequency |
0.1HZ ~ 400HZ |
| Frequency Setting
Resolution |
0.1HZ |
|
Output Frequency Resolution |
0.1HZ |
| PWM Carrier
Frequency |
2K ~ 16K |
|
Torque Boost |
1. Torque boost and slip compensate automatically.
2. Start Torque: 150% /
5HZ. |
| Frequency Jump |
0.1 ~ 400HZ (3
Steps abailable) |
|
Acc. / Dec. Time |
0.2 ~ 1200 Sec (Acc. / Dec. Time setting independently, 4 steps available) |
| Stall Prevention
Level |
50 ~ 200% rated
current setting. |
|
DC Braking |
0-25 Sec (0-0.2PU rated voltage braking) |
| Dynamic braking
torque |
1. Approx. 20% (Up
to 120% with option)
2. Braking resistor build-in. |
|
V/F Curve |
V/F Curve adjustable. |
Note: CSA cus approval for
AP2G3-110~220, AP4G3-150~220
|
|
|
|
|
|
|
OPERATION FEATURE |
| Frequency setting |
Digital operator |
Press
for setting. |
|
Operation |
External terminal |
0 ~ 10VDC, 4-20mA, serial interface (RS-485) |
|
Digital input terminal |
Digital operator |
Press
to operate. |
|
External terminal |
2 Wire (Fwd /
Stop. Rev / Stop. Run / Stop. Fwd / Rev) / 3 wire operation. |
| Jog |
|
Digital input terminal |
8 Presetting speeds. 4 Acc. / Dec. options. |
|
Fault signal input, Jog. |
|
Max. Voltage selection, 3 wire stop. |
|
Digital output terminal |
Frequency arrival
open collector output. |
| Pulse frequency /
period adjustable. |
| Low Voltage
detect. Fault signal output. External fault output. |
|
Analog output (PWM) |
Convert inverter output frequency or current to Analog signal. |
| Fault
signal output |
Inverter fault
signal output. (1a1b) |
|
Built-in function |
Max. / Min. frequency setting. Instantaneous power "OFF" restart, fault
restart. |
|
S curve / Acc. / Dec. time setting. |
|
Digital output frequency signal, error record, parameter lock. |
Operation direction limit, over current stall prevention protection, over
voltage stall prevention protection. Over load protection. |
|
Protection |
Over voltage, over
current, under voltage, motor over load, over heat. |
| Phase to phase
short circuit / motor case to earth short circuit. |
|
Digital operator |
Including 8 function key, 6 digital 7 segment LED display. 4 status
indication LEDS. |
Frequency setting, output frequency display. Output current display, user
self-definition. |
|
Parameter view, Modify and lock, error display. |
|
Executing "RUN", "STOP", "RESET", "FWD/RED", "JOG" command. |
|
|
|
|
|
|
|
ENVIRONMENTS |
|
Operation ambient temperature |
-10oC
to + 40oC (+ 40oC ~ + 50oC
Shall open front case) |
|
Storage
temperature |
-20oC
to + 60oC |
|
Operation humid |
Below 90% RH,
no frost |
|
|
|
|
|
|
Vector
Inverter Dimension |
|
|
[
Fig1 ]
|
|
|

|
|
|
[
Fig2
]
|
|
|

|
|
|
[
F306 Remote Control
panel ]
|
|
|

|
|
|
|
|
|
Wire